Temperature Controlled Single-Axis Motion Simulators Test Turntable for Vibration Sensor Calibration
Product Description
Model 1LT300 single-axis multi-function turntable is a mature and finalized precision single-axis rate test equipment, which is mainly used for various position, rate and swing tests and detection of rate gyroscope and its inertial measurement unit. After the temperature control box, the temperature control system, the auxiliary shaft and other parts are selected, the turntable can also be applied to the performance test of the inertial navigation device and the inertial navigation system under the low temperature condition. The supporting computer of the turntable has the function of storing the data related to the operation of the turntable, such as the real-time value of time, turntable position, speed and temperature of the turntable body, and has the function of outputting the data in real time through the string, and can control the turntable and the temperature through the external computer (through the string).
Product Parameters
No. | Project | Indicators |
1 | The structure is open | Vertical or horizontal |
2 | Load |
Not more than 30 kg |
3 | Table top |
Not less than Ø 300mm |
4 | Degree of platform work | 350mm |
4 | Flatness of platform | 0.02mm |
5 | Table face runout | 0.05mm |
6 | Rotation accuracy of shafting | ±3″ |
7 | Location range | ±0~±360° |
8 | Position accuracy | ± 3 ″ (optional) |
9 | Measure the resolution | 0.0001° |
10 | Speed range, deg/sec |
0.001 ~ ± 10000 deg/sec (optional) |
11 |
Rate accuracy , % Rate accuracy |
ω<1°/s 1×10-3 1°/s<ω<10°/s 1×10-4 10°/s<ω 5×10-5 |
12 | Rate resolution | 0.0001°/s |
13 | Max acceleration, deg/sec 2 |
10000 deg/sec2 |
14 | Axis wobble, arcsec |
It has functions |
15 | Slipping rings |
50 pcs., 2А/150V DC |
16 | Communication interface |
RS232,Ethernet |
17 | Bandwidth, Hz, not less |
5 ~ 100Hz optional |
18 | Magnetic flux leakage | <0.5mT |
19 | MTBF | ≥2000h |
Operating conditions of turntable
1. Power supply: 220V ± 10% 50 Hz 15 A
2. Ambient temperature 10 ºC ~ 35 ºC
3. Ambient humidity 15% ~ 80% RH
4. Common vibration isolation foundation in foundation environment
Applicatin Areas